Описание

  • Locking module (order handle module separately)
  • Adjustable door hinge, factory setting: right
  • Series connection possible (up to 20 AR devices in series)
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • Emergency stop
  • Two pushbuttons (illuminated)
  • With plug connector M23
  • Unicode
  • Door monitoring output
  • With escape release (order inner door handle separately)
Door hinge The door hinge can be changed. Each handle module is unique. The locking module detects only handle modules that have been taught in. Additional handle modules can be taught in. Only the last handle module taught in is detected. Guard locking type
MGBS-L1Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle)
Lens set The color of the pushbutton can be selected using the lens set included (five colors). Escape release Is used for the manual release of the guard locking without tools. The inner door handle permits escape from the danger zone. Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connecting cable
1 IMPB Operating voltage of guard locking solenoid 24 V DC VT
2 FI1A Enable input, channel 1 RD
3 FI1B Enable input, channel 2 GY
4 FO1A Safety output, channel 1 RD/BU
5 FO1B Safety output, channel 2 GN
6 UB Operating voltage of AR electronics, controls and indicators 24 V DC BU
7 RST Reset input GY/PK
8 OD Door monitoring output GN/WH
9 OI Diagnostic output YE/WH
10 S1.A1 EMERGENCY STOP (channel A) GY/WH
11 S1.A2 EMERGENCY STOP (channel A) BK
12 FE Function earth (must be connected to meet the EMC requirements) GN/YE
13 S1.B1 EMERGENCY STOP (channel B) PK
14 S1.B2 EMERGENCY STOP (channel B) BN/GY
15 S2 Pushbutton 2 (illuminated) BN/YE
16 H2 LED 2 BN/GN
17 S3 Pushbutton 3 (illuminated) WH
18 H3 LED 3 YE
19 0 V Operating voltage of AR electronics, controls and indicators 0 V/guard locking solenoid 0 V BN
Housing material
Switch bracket Die-cast zinc
Safety switch housing Fiber glass reinforced thermoplastic
Weight
Net 1,5 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protection IP65
Resilience to vibration In acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation orientation Door hinge DIN right
Ready delay 8 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M23, 19-pin, RC18
Approach speed 20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm
Electrical connection ratings
Test-pulse interval min.140 ms
Test pulses max.1,0 ms
Operating voltage DC
UUB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
IUB 40 mA
IIMP 400 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (solenoid operating voltage IMP) 0,5 ... 8 A
External (operating voltage UB) 0,25 ... 2 A
Rated insulation voltage Ui max.50 V
Rated impulse withstand voltage Uimp max.0,5 kV
Power consumption 6 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
Risk time according to EN 60947-5-3
Delay per device 5 ms
Single device max.260 ms
Switching load
According to UL 24V DC, class 2
Safety outputs FO1A / FO1B
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
High U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
Low U(FO1A) / U(FO1B) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Switch-on time max.400 ms
Discrepancy time
Both safety outputs max.10 ms In acc. with EN IEC 60947-5-3
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OI
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Controls and indicators
Operating voltage UB V
Operating current 1 ... 50 mA
Power supply
LED 24 V
Current consumption
LED 10 mA
Emergency stop
Operating voltage 5 ... 24 V
Operating current 1 ... 100 mA
Work area
Repeat accuracy R 10 %
Controls and indicators
Position 1
Ausfuhrung Emergency stop
Einlegeschild
Extras
Farbe
Schaltelement 2 pos. driven NC
Position 2
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 3
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Other
Additional feature
Incl. cover set ID. No. 120344
Escape release actuated by pushing
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Emergency stop
B10D 0,065 x 106
Performance Level PL e
Category 4
PFHD 4.1 x 10 -9
Mission time 20 y
''